Skip to main content

Table 4 Model for LVEF measured by cardiac catheterization (reference echocardiogram) and not early (reference Early) (N = 445, no of events = 52)

From: In-hospital measurement of left ventricular ejection fraction and one-year outcomes in acute coronary syndromes: results from the IMMEDIATE Trial

Variable

HR (95 % CI)

P value

LVEF/5 % lower (combined)

1.25 (1.14, 1.37)

< 0.001

 Age/10 years Increase

1.71 (1.36, 2.15)

< 0.001

 History of CAD (MI, PCI, or CABG)

2.94 (1.60, 5.40)

< 0.001

 LVEF - echocardiogram (reference catheterization)

1.62 (0.93, 2.80)

0.08

LVEF/5 % lower (combined)

1.25 (1.13, 1.36)

< 0.001

 Age/10 years Increase

1.71 (1.36, 2.15)

< 0.001

 History of CAD (MI, PCI, or CABG)

2.86 (1.56, 5.26)

< 0.001

 LVEF - not early (reference early)

1.53 (0.86, 2.69)

0.14